Container damage location code builder (IICL / CEDEX)

Repair estimates (WESTIM), gate-in/out interchange reports and EDI messages pin each damage to a 4-character location code, following the convention in IICL Technical Bulletin TB 002 and ISO 9897 (CEDEX). Build a code here or decode one you received.

Build a location code

1. Face of the container
2. Segment
3. Sections along the length

RT24

Right side · Top half · sections 2 to 4 (adjacent sections)

Read a location code

Reference

Section 1 is at one end of the face and numbering runs along the length; check your customer's location diagram for which end section 1 starts at. Numbered components (cross members, roof bows, side posts) are counted from the door end, and listed in the comments, e.g. “CMA 1, 3, 6, 9”.

1st character: face
CodeFace
RRight side
LLeft side
TRoof (top)
BBottom (floor)
FFront end
DDoor end (rear)
UUnderstructure
IInterior
EExterior
XWhole container
2nd character: segment
CodeSegment
HUpper component
GLower component
TTop half
BBottom half
LLeft half
RRight half
XBoth halves / whole face
Front / door end positions (across the width)
CodePosition
1left corner post
2left half
3right half
4right corner post
3rd–4th characters
CodeMeaning
5NOne section only (section 5)
24Adjacent sections 2 to 4
XXFull length (or width) of the face
Responsibility (party) codes
CodeParty
UUser / lessee
OOwner / lessor
DDepot
IDPP / insurance
JJoint survey allocation assigned
RLessee refused
SCentral billing
TThird party
Material type codes
CodeMaterial
SKSteel, Corten
STSteel, carbon
SGSteel, galvanised
SUSteel
AUAluminium
APAluminium, pre-painted
PPPlywood
PMPlymetal
WUWood
WHWood, hard plank
WSWood, soft plank
LHWood, hard laminated plank
LSWood, soft laminated plank
RURubber

Source: IICL TB 002, Preferred Electronic Data Interchange Standards (rev. May 12, 2022). Component, damage and repair codes are published in ISO 9897 and the IICL Equipment Code Standards (iicl.org).

Frequently asked questions

How is a container damage location code structured?

Character 1 is the face (R right side, L left side, T roof, B floor, F front, D door, U understructure, I interior, E exterior, X whole container). Character 2 is the segment (H upper, G lower, T top half, B bottom half, L left half, R right half, X both). Characters 3–4 give the section(s): one section plus N, two section numbers for a run of adjacent sections, or XX for the full length.

How many sections does a container side have?

Sides, roof, floor and understructure are divided into equal sections of roughly 1.2 m (4 ft): 5 sections on a 20 ft container (1–5) and 10 on a 40 ft (1–9, then 0).

What does RT24 mean?

Right side (R), top half (T), from section 2 to section 4.

Where do I get component, damage and repair codes?

They're defined in ISO 9897 (CEDEX) and in IICL's Equipment Code Standards (ECS), which list the recommended component, damage and repair codes and combinations. Many lessors also issue their own code lists, so follow your customer's operating instructions.