Container damage location code builder (IICL / CEDEX)
Repair estimates (WESTIM), gate-in/out interchange reports and EDI messages pin each damage to a 4-character location code, following the convention in IICL Technical Bulletin TB 002 and ISO 9897 (CEDEX). Build a code here or decode one you received.
Build a location code
RT24
Right side · Top half · sections 2 to 4 (adjacent sections)
Read a location code
Reference
Section 1 is at one end of the face and numbering runs along the length; check your customer's location diagram for which end section 1 starts at. Numbered components (cross members, roof bows, side posts) are counted from the door end, and listed in the comments, e.g. “CMA 1, 3, 6, 9”.
| Code | Face |
|---|---|
| R | Right side |
| L | Left side |
| T | Roof (top) |
| B | Bottom (floor) |
| F | Front end |
| D | Door end (rear) |
| U | Understructure |
| I | Interior |
| E | Exterior |
| X | Whole container |
| Code | Segment |
|---|---|
| H | Upper component |
| G | Lower component |
| T | Top half |
| B | Bottom half |
| L | Left half |
| R | Right half |
| X | Both halves / whole face |
| Code | Position |
|---|---|
| 1 | left corner post |
| 2 | left half |
| 3 | right half |
| 4 | right corner post |
| Code | Meaning |
|---|---|
| 5N | One section only (section 5) |
| 24 | Adjacent sections 2 to 4 |
| XX | Full length (or width) of the face |
| Code | Party |
|---|---|
| U | User / lessee |
| O | Owner / lessor |
| D | Depot |
| I | DPP / insurance |
| J | Joint survey allocation assigned |
| R | Lessee refused |
| S | Central billing |
| T | Third party |
| Code | Material |
|---|---|
| SK | Steel, Corten |
| ST | Steel, carbon |
| SG | Steel, galvanised |
| SU | Steel |
| AU | Aluminium |
| AP | Aluminium, pre-painted |
| PP | Plywood |
| PM | Plymetal |
| WU | Wood |
| WH | Wood, hard plank |
| WS | Wood, soft plank |
| LH | Wood, hard laminated plank |
| LS | Wood, soft laminated plank |
| RU | Rubber |
Source: IICL TB 002, Preferred Electronic Data Interchange Standards (rev. May 12, 2022). Component, damage and repair codes are published in ISO 9897 and the IICL Equipment Code Standards (iicl.org).
Frequently asked questions
How is a container damage location code structured?
Character 1 is the face (R right side, L left side, T roof, B floor, F front, D door, U understructure, I interior, E exterior, X whole container). Character 2 is the segment (H upper, G lower, T top half, B bottom half, L left half, R right half, X both). Characters 3–4 give the section(s): one section plus N, two section numbers for a run of adjacent sections, or XX for the full length.
How many sections does a container side have?
Sides, roof, floor and understructure are divided into equal sections of roughly 1.2 m (4 ft): 5 sections on a 20 ft container (1–5) and 10 on a 40 ft (1–9, then 0).
What does RT24 mean?
Right side (R), top half (T), from section 2 to section 4.
Where do I get component, damage and repair codes?
They're defined in ISO 9897 (CEDEX) and in IICL's Equipment Code Standards (ECS), which list the recommended component, damage and repair codes and combinations. Many lessors also issue their own code lists, so follow your customer's operating instructions.